Manual STS6/17 Controller

Manual STS6/17Controller, With or Without amplitude sensor

This operating instruction applies to:

Type BoxColourDimensionsCode
STS6Fire-retardant plasticRAL 7040165 x 130 x 70STS6 Z4 STP
STS6AluminumGray165 x 140 x 65STS6 Z4 STM
STS6Metallic BoxGray240 x 130 x 110STS6 Z4 STD
STS6Circuit145 x 115 x 45STS6 A4 STD
STS6Circuit145 x 140 x 55STS6 D4 STD
STS6AluminumRAL 7035195 x 130 x 90STS6 Z4 SM1

Norms of guarantee

  1. The controller is guaranteed for a period of 2 years from the date shown on the inside.
  2. The guarantee covers the free replacement or repair of components parts that are defective at origin for manufacturing
  3. The guarantee is not valid for damage caused accidentally due to improper use or negligence and in case of alterations or repair carried out by unauthorized persons.

Design and specifications could be subjected to change without notice

DECLARATION OF CONFORMITY

This equipment conforms with ecc directive 2014/30/UE (EMC – Electromagnetic Compatibility) and directive 2014/35/UE (LVD – Low Voltage Directive)

 

Replacement policy

Please contact us through our contact page – Contact

Safety instructions


Indicates an immediate threatening danger.

Non-compliance with this information can result in death or serious personal injuries (invalidity).

 

 

Indicates a possibly dangerous situation.

Non-compliance with this information can result in death or serious personal injuries (invalidity).

 

 

 

Indicates a possibly dangerous situation.

Non-compliance with this information can result in damage to property or .light to medium personal injuries.

 

 

 

Indicates general notes, useful operator tips and operating recommendations which don’t affect safety and health of the personnel.

Before using the appliance it is necessary to read attentively the instructions included in this technical sheet which provides you information about safety installation, use and maintenance. keep this sheet safely for further information.

 

 

 

 

General instructions

Before connect the equipment to the mains socket, make sure that the nameplate data match those of the mains power supply.

Only use this equipment in accordance with the porpouse for which it is designed; i.e. for regolation of the amplitude of an electromagnetic vibrator feeder. Any other use is to considered improper, therefore hazardous.

The Manufacturer cannot be held liable for any improper, incorrect or unreasonable use of the equipment, switch it off and do not tamper with it. If repair is needed, please contact the Manufacturer’s Technical.

Service Centre only, as they use original spare parts. Failure to observe the above the recommendations could impair the safety of the equipment.

All operations regarding adjustement, measurement and testing when required, must only be carried out by authorized and qualified personnel.

The Manufacturer shall accept no liability for damage to persons, animals or objects caused by work on the equipment carried out by unauthorized and unqualifield personnel.

Before switching on the equipment, connect the mains voltage, conforming to the current regulation, and the vibratory feeder.

 

Verifying that the installation has an appropriate ground wiring system.

TURN OFF THE POWER BEFORE OPENING.

 

 

 

NOTE : Don’t use the apparatus in proximity of subject zones to vibrations, or in acid and humid working environment

If vibratory feeder doesn’t work properly:

  • Check electric wires, to check regolation MIN/MAX.
  • Switch OFF voltage and to check the fuses and, this case, to check current MAX (ampere) in the vibrator.
  • Check MANUAL/AUTOMATIC position on MR2.
  • Check DIP3 (Normally ON)

 

Technical characteristics

Circuit Type: STS6Input impedance 0/10V - 4/20mA 50Kohm - 50 ohm
Feeding tension: 115V or 230V or 400V ± 20% 50/60 Degree Of Protection: IP55 (IP65) in box (only circuit IP00)
Consumption: 1,5 W Max Degree Of Pollution: 2
Max current: 6,3A RMS (8A on request)Min. load 50mA RMS
Fuses:
230V double 6,3 F 500V 6,3x32 H 1500A
400V double 6,3 F 500V 6,3x32 H 1500A
Degree Of Pollution: 2
Potentiometer Of Reg.: 100K Ohm LinearStorage temperature: -30 °C / + 80 °C
Vibration frequency: 3000/6000V/m (50Hz)
3000/7200V/m (60Hz)
Operation temperature: -20 °C / + 50 °C
Ramp time: 1 sec Range Of Relative Humidity: 80% Till to 31°C
Min. regulation: 80V 30% (230V) 140V 30% (400V) Installation Class: II
Max. regulation: 200V - 30% (230V) 380V-30% (400V) Altitude: Till to 2000 Meters
Input On/Off: Contact 0-24VccAUTOMATIC INPUT CONSUMPTION 0/10V: 1mA max
AUTOMATIC INPUT CONSUMPTION 0/10V: 1mA max

Wave Forms

 

Description waveforms figures (above)

Supply controller (yellow)
Output vibrator (blue)
Frequency: 50 Hz – 3000 V/m (vibrator)

Figure statististics

  • Fig. 1 : Output V/max 216V
  • Fig. 2 : Output V/medio 160V
  • Fig. 3 : Output V/min 52V

 

Instructions

Before give voltage to the controller connect the supply voltage (clamps 2-3 CONN1), verifying that the installation has an appropriate ground wiring system and the vibrator (clamps VIBRATOR – CONN 2) of the connector (1-4 ground).

According European Norms EMC the controller have a line-filter with leakage current to ground less 1 mA.
To adjust intensity of vibration of the vibratory feeder, turn the adjustment knob (potentiometer 100K) on the box.

 

 

Regulation MIN/MAX

To adjust the Min./Max voltage of the vibratory feeder, proceed as follows :
MIN REG.: Turn the potentiometer to minimum, then set the minimum vibration by means of relative trimmer TR1.
MAX REG. : Turn the potentiometer to maximum, then set the maximum vibration by means of relative trimmer TR2.
N.B. : Use a small bladed screw driver in order not to damage the trimmer. Turn it in vertical direction respect to the PC board.

 

Automatic Input

The vibratory feeder can be regulated with an external signal (0/10V or 0/20mA). To do so, proceed as follows:
Shift jumper Y3 on AUTOMATIC.
Supply an input signal, 0/10V (1-3 CONN2) or 4/20mA (1-2 CONN2) to regulate the vibratory feeder.
The trimmers for the automatic regulation could be used for regulate the minimum and / or the maximum voltage

ON/OFF

The vibratory feeder can be switched off by contact without voltage, using the auxiliary ON/OFF input (1-CONN3
and 1-CONN2) o signal voltage 0-24 VDC (1-CONN3 and 1-CONN2) with logic 0/1 (jumper Y4).

3000/6000 V/M

It is possible to change the frequency of vibration 3000V/m-50Hz (3600V/m-60Hz) or 6000V/m-100Hz (7200V/m-
120Hz) by DP1; before switch off the voltage.

0-24v signal:
Use input 1-2 CONN5 with a 0-24 Vdc signal.
With the DP3 it is possible to turn the ON / OFF logic through the 0-24 V signal or free contact voltage.

Start Ramp

Is possible to change the time of the start ramp (slow 1 sec or fast 0,1 sec) by DP2.

3000/6000 V/m

Is possible to change the frequency of vibration 3000V/m-50Hz (3600V/m-60Hz) or 6000V/m- 100Hz (7200V/m-120Hz) by DP1; before switch off the voltage.

 

Double Speed

It is possible (on request) to have nr.2 speed (hight and slow speed ) with 2 potentiometers (see catalogue’s sheet DTCV2V)

 

 

 

Note trimmer TR5
The circuit is supplied already calibrated, However it may happen that the vibrator has a vibration different from the standard one.

To solve the problem, simply use the sensitivity adjustment trimmer (TR5) on the circuit STS6 / STS8 in order to adapt
the operation to vibrators with very different vibration amplitudes.

This trimmer moves both the minimum and maximum limits, centering the desired variation. If you have a RMS voltage meter (volmeter), even acting on the min and max trimmers placed on the board, set the Min. to 70 / 90V. at 230V
and 140 / 160V at 400V and the Max. at 190 / 200V at 230V and 330 / 360V at 400V. For the optimal operating point, the following considerations apply: if the circuit is optimized with an empty vibrator, the working point must be placed sufficiently below the line voltage so that by weighing down with the load, the circuit can keep the vibration stable by giving more voltage output. On the other hand, by optimizing with the vibrator at full load, the voltage on the vibrator can only go down as the channel or bowl empties and the working point may be closer to the line voltage.

Note trimmer TR3 – SMOOTH

STS6 or STS8 circuits are supplied with response times that do not give swing problems in the majority of cases.

However, it is possible to change this response time by acting on the TR3 trimmer. Turning it clockwise lengthens the time and it is possible to optimize the operation of particularly sensitive vibrators. On the other hand, turning it anticlockwise the response time is shortened (SLOW) and it is possible to use short break/work. This, however, on vibrators sufficiently rigid. In any case, at the first hint, this time must be lengthened
long enough to eliminate it.

On the other hand, it is practically impossible to expect short response time using very sensitive vibrators. In this
case it is necessary to act mechanically on vibrators.